OKB-T

Application

  • OKB-T cable is designed for installation in grounds of 1-3 groups, cable ducts, tunnels in case of high requirements of crush strength.
  • OKB-T cable with flame retardant protective jacket is designed for installation according to exclusive standards of fire safety.
OKB-T
  1. Optical fiber
  2. PBT loose tube filled with hydrophobic gel
  3. Zink-coated steel wire armor
  4.  Protective jacket
* longitudinal watertightness of the cable is provided by a hydrophobic gel
(8342) 473-813, 480-299
Number of fibers
2-16
18-24
26-36
38-48
Nominal overall diameter, mm
8,7
10,2
11,2
11,4
Total mass of cable with polyethylene jacket (kg/km)
122
166
199
209

* the data correspond to a cable of 7kN

** total mass of the cable with flame retardant protective jacket is specified when ordering

Temperature range of operation, С°
-40… +60
Temperature range of installation, С°
not lower then -30**
Minimal bending radius
not less than 20 diameters
Lifetime
25 years
Guarantee exploitation
2 years after putting in operation, not more than 2,5 years from shipping date
Tensile strength
not less than 2,5 kN for laying in grounds of 1-3 groups;
not less than 4 kN for laying in grounds of 4-5 groups;
Crush strength
not less than 4 kN/100 mm for laying in grounds of 1-3 groups;
not less than 7 kN for laying in grounds of 4-5 groups;

** In case of cable with flame retardant protective jacket, the min. installation temperature is not lower than -10 °С.