U/UTP Сat 5e PE with steel rope

Application

Unshielded Twisted Pair (U/UTP) with steel rope and Polyethylene sheathdesigned for outdoor laying by suspension and operation in structured cabling systems according to international standard ISO / IEC 11801 and broadband access networks in the frequency range up to 100 MHz at operating voltages not exceeding 75 V.

  • Cable outer sheath is made of polyethylene.
  • All Category 5e LAN cables manufactured by "Saranskkabel-Optika",Ltd. comply with GOST R 54429-2011. Cables are delivered by 305 meters in coils or on plywood drums with a diameter of 400 mm, 600 mm.
U/UTP Сat 5e PE with steel rope
  1. Copper conductor
  2. Polyethylene insulation with individual color marking of each insulated core
  3. Polyethylene terephthalate (PET) tape
  4. Steel rope
  5. Outer sheath: Polyethylene
(8342) 473-813, 480-299
Weight and size specifications
Number of pairs 4
Nominal outer diameter of sheath over conductive core, mm 5,35
Nominal outer diameter of sheath over steel rope, mm 2.5
Cable nominal weight, kg/km 40,2
Copper conductor diameter (mm) 0,51 mm (24 AWG)*
Mechanical characteristics
Maximum tensile force of steel rope Not less 1,2 kN
Breaking force of outer sheath Not less 9МPa
Bending radius Not less than 8 diameters
Transmission characteristics
Name Value
Frequency, MHz Up to 100
Characteristic impedance in the frequency range (1-100) MHz, Ohm 100±15

Attenuation, dB / 100m, not more than:
at a frequency of 4 MHz
at a frequency of 20 MHz
at a frequency of 100 MHz


4,1
9,3
22,0

NEXT, dB / 100m, not less:
at a frequency of 4 MHz
at a frequency of 20 MHz
at a frequency of 100 MHz


56,3
45,8
35,3

FEXT, dB / 100m, not less:
at a frequency of 4 MHz
at a frequency of 20 MHz
at a frequency of 100 MHz


52,0
38,0
24,0

Return loss (RL), dB / 100m, not less:
at a frequency of 4 MHz
at a frequency of 20 MHz
at a frequency of 100 MHz


23,0
25,0
20,1

Steam capacity, not more, nF / km 56
*It is possible to manufacture cables with conductive core diameter up to 0,52 mm.
Color code/ Pair identification
Insulation colour
Pair number
Wire a
Wire b
1 Blue White blue stripes
2 Orange White orange stripes
3 Green White green stripes
4 Brown White brown stripes
Cables can be operated at temperatures: - 40 °С+ 60 °С.
Checking and installation of cables should be carried out at ambient temperature - not below - 10 °С.
Bending radius of cables during installation should be at least 8 maximum outer diameters of the cable. In the process of laying, installation and operation of cables it is not allowed for moisture or soil electrolytes to get under the cable sheath through its ends.
Feeding inside the cable and/or applying substances harmful to cable elements to the cable sheath is not allowed.