U/UTP Cat 6 PE

Application

Symmetrical communication cables are designed for operation in structured cabling systems according to the international standard ISO/IEC 11801 and in broadband access networks in the frequency range up to 250 MHz at operating voltage not more than 75 V.

  • Core diameter 0,54 mm.
  • Number of pairs: 4.

All LAN-cables of category 6 produced by Saranskkabel-Optika Ltd. conform to GOST R 54429-2011. The cables are delivered in cardboard boxes of 305 metres or on plywood drums with a cheek diameter of 400mm.

U/UTP Cat 6 PE
  1. Copper conductor with a diameter of at least 0.54 mm
  2. Polyethylene insulation with individual colour marking of each insulated conductor
  3. Cross-shaped separator
  4. PET (polyethylene terephthalate) tape
  5. Outer sheath (Polyethylene)
(8342) 473-813, 480-299
Weight and size specifications
Number of pairs 4
Cable nominal diameter, mm 6,0
Cable nominal weight, kg/km 33,59
Copper conductor diameter, mm 0,54
Mechanical characteristics
Maximum tensile force
50 N
Breaking force of outer sheath
Not less 9МPa
Bending radius
Not less than 8 diameters
Transmission characteristics
Frequency, MHz Up to 250
Characteristic impedance in the frequency range (1-100) MHz, Ohm 100±15

Attenuation, dB / 100m, not more than:

- at a frequency of 4 MHz

- at a frequency of 20 MHz

- at a frequency of 100 MHz

- at a frequency of 250 MHz

3,8

8,5

19,9

33,0

NEXT, dB / 100m, not less::

- at a frequency of 4 MHz

- at a frequency of 20 MHz

- at a frequency of 100 MHz

- at a frequency of 250 MHz

66,3

55,8

45,3

39,3

FEXT, dB / 100m, not less:

- at a frequency of 4 MHz

- at a frequency of 20 MHz

- at a frequency of 100 MHz

- at a frequency of 250 MHz

56,0

42,0

28,0

20,0

Return loss (RL), dB / 100m, not less:

- at a frequency of 4 MHz

- at a frequency of 20 MHz

- at a frequency of 100 MHz

- at a frequency of 250 MHz

23,0

25,0

20,1

18,0

Electrical capacity of pairs, not more, nF / km 56
Color code/ Pair identification
Insulation colour
Pair number
Wire a
Wire b
1 Blue White blue stripes
2 Orange White orange stripes
3 Green White green stripes
4 Brown White brown stripes

Temperature range of operation, С°: -60… +60

Temperature range of installation, С°: not lower then -20

Minimal bending radius: not less than 8 diameters

Lifetime: 25 years