F/UTP Cat 5e multi-pair

Application

  • Symmetrical communication cables are designed for use in structured cabling systems according to the international standard ISO/IEC 11801. The data transmission rate is up to 10 Gbit/sec with a maximum bandwidth of 100 MHz. They are used for outdoor fixed installation in low voltage networks.
F/UTP Cat 5e multi-pair
  1. Annealed copper conductor with a diameter of 0.51 mm (24 AWG)
  2. Polyethylene insulation with individual color coding of each insulated core
  3. Identification thread
  4. Polyethylene terephthalate (PET) tape
  5. Alumoflex tape and tinned copper conductor
  6. Outer sheath: Polyethylene (PE)
(8342) 473-813, 480-299
Weight and size specifications
Number of pairs
25
Cable nominal diameter, mm
12,8±0,20
Cable nominal weight, kg/km
160
Copper conductor diameter, mm
0,515+0,005 (24 AWG)
Mechanical characteristics
Maximum tensile force, N
50
Breaking force of outer sheath, MPa
Not less 9
Bending radius
Not less than 8 diameters
Transmission characteristics
Frequency, MHz
Up to 100
Characteristic impedance in the frequency range (1-100) MHz, Ohm
100±15
Attenuation, dB / 100m, not more than:
at a frequency of 4 MHz
at a frequency of 20 MHz
at a frequency of 100 MHz

4,1
9,3
22,0
NEXT, dB / 100m, not less:
at a frequency of 4 MHz
at a frequency of 20 MHz
at a frequency of 100 MHz

56,3
45,8
35,3
FEXT, dB / 100m, not less:
at a frequency of 4 MHz
at a frequency of 20 MHz
at a frequency of 100 MHz

52,0
38,0
24,0
Return loss (RL), dB / 100m, not less:
at a frequency of 4 MHz
at a frequency of 20 MHz
at a frequency of 100 MHz

23,0
25,0
20,1
Steam capacity, not more, nF / km
56
Color code/ Pair identification
Insulation colour
Pair number
Wire a
Wire b
1 Blue White blue stripes
2 Orange White orange stripes
3 Green White green stripes
4 Brown White brown stripes
Operational requirements
Temperature range of operation, С°
-40… +60
Temperature range of installation, С°
not lower then -10
Minimal bending radius
not less than 8 diameters
Lifetime
15 years
Guarantee exploitation
3 years after putting in operation
Not allowed
Moisture or soil electrolytes may not enter the cable sheath through its ends
Application to the cable sheath substances, harmful to the cable elements