U/UTP Category 5e (PE)

Application

  • Unshielded Twisted Pair (UTP) with Polyethylene sheath is designed for outdoor installation in telephone conduits, collectors, mines, along the walls of buildings and in broadband access networks in the frequency range up to 100 MHz with an operating voltage of not more than 145 V.
U/UTP Category 5e (PE)
  1. Annealed copper conductor 0.51 mm diameter (24 AWG)
  2. Polyethylene insulation with individual color marking of each insulated core
  3. Polyethylene terephthalate (PET) tape
  4. Outer sheath: Polyethylene
(8342) 473-813, 480-299
Weight and size specifications
Number of pairs
2
4
Cable nominal diameter, mm
4,45 (+- 0,1)
5,15 (+- 0,1)
Cable nominal weight, kg/km
16,22
27,50
Copper conductor diameter, mm
0,51 мм (24 AWG)
Mechanical characteristics
Maximum tensile force
50 N
Breaking force of outer sheath
Not less 9МPa
Bending radius
Not less than 8 diameters
Transmission characteristics
Frequency, MHz
Up to 100
Characteristic impedance in the frequency range (1-100) MHz, Ohm
100±15
Attenuation, dB / 100m, not more than:
at a frequency of 4 MHz
at a frequency of 20 MHz
at a frequency of 100 MHz

4,1
9,3
22,0
NEXT, dB / 100m, not less:
at a frequency of 4 MHz
at a frequency of 20 MHz
at a frequency of 100 MHz

56,3
45,8
35,3
FEXT, dB / 100m, not less:
at a frequency of 4 MHz
at a frequency of 20 MHz
at a frequency of 100 MHz

52,0
38,0
24,0
Return loss (RL), dB / 100m, not less:
at a frequency of 4 MHz
at a frequency of 20 MHz
at a frequency of 100 MHz

23,0
25,0
20,1
Steam capacity, not more, nF / km
56
Color code/ Pair identification
Insulation colour
Pair number
Wire a
Wire b
1 Blue White blue stripes
2 Orange White orange stripes
3 Green White green stripes
4 Brown White brown stripes
Temperature range of operation, С°
-60… +60
Temperature range of installation, С°
not lower then -20
Minimal bending radius
not less than 8 diameters
Lifetime
15 years
Guarantee exploitation
3 years after putting in operation